Will deleting old emails and photos really save water?
The claim: “Delete old emails and pictures as data centres require vast amounts of water to cool their systems.”
Short answerNo. The saving is far too small to notice.
No. Data centres do use water to keep cool, but stored files are a small part of their work: storage systems use about 5% of data-centre electricity (IEA). Hum’s sums: one 18 TB data-centre drive idles at 5.3 W. So 1,000 photos of 5 MB, kept as 3 copies, use about 39 Wh a year, about 2 phone charges. At 1 to 9 litres of water per kWh at the data centre (Li et al.), plus 3.14 at US power stations, that’s about 160 to 470 ml a year. The same government advice says a leaky loo can waste 200 to 400 litres a day: about 426 times more, every single day. Andy Masley, an independent writer, worked out you’d need to delete 1.5 billion photos, or 200 billion emails, to match fixing one leaky toilet.
The bigger pictureWhat did help: Yorkshire Water reported a 10% fall in home water use after its hosepipe ban, up to 80 million litres a day. Data-centre water is real but local: US data centres consumed about 17 billion US gallons (about 64 billion litres) on site in a recent year (a Berkeley Lab estimate).
What this means for you: your own use barely registers. What adds up is billions of questions, heavier uses like thinking modes and video, and the data centres being built for them.
Wh is a watt-hour: a 1-watt light left on for an hour. 1 kWh = 1,000 Wh. 1 TWh = 1 billion kWh.
Why the claim misleads
It points at something real, data-centre cooling water, but at a part of it, stored files, that is far too small to matter. The advice gave no figure.
What nobody knows yet
- Nobody has measured whether deleting files makes a data centre use any less water. Drives may keep running either way, and copies can stay in backups.
- Hum’s sums count the drive only, not the servers, network and cooling around it, so the true figure is somewhat higher, though still tiny next to a leak.
- A per-email water figure said to come from the Environment Agency appears in news stories, but Hum couldn’t find it on any government page.
- Hum found no published total for the water UK data centres use.
Sources (12)
- UK Environment Agency and Defra, National Drought Group press release (August 2025) News report
“Delete old emails and pictures as data centres require vast amounts of water to cool their systems.”
Quote checked on the page, 8 Nov 2026 - UK Environment Agency and Defra, National Drought Group press release (August 2025) Estimated
“Fix a leaking toilet – leaky loos can waste 200-400 litres a day.”
Quote checked on the page, 8 Nov 2026 - UK Environment Agency and Defra, National Drought Group press release (August 2025), reporting Yorkshire Water’s figure Estimated
“Yorkshire Water reporting a 10% reduction in domestic demand following their hosepipe ban. This equates to saving up to 80 million litres per day”
Quote checked on the page, 8 Nov 2026 - IEA, Energy and AI (2025): share of data-centre electricity by equipment Estimated
“Storage systems are devices used for centralised data storage and backup, and account for around 5% of electricity consumption.”
Quote checked on the page, 8 Nov 2026 - Seagate, Exos X18 data sheet (data-centre hard drive) Company says so
“Market-leading 18TB HDD”
Quote checked on the page, 8 Nov 2026 - Seagate, Exos X18 data sheet, power table (first column: the 18TB SATA model) Company says so
“Idle A (W) Average 5.3W”
Quote checked on the page, 8 Nov 2026 - Seagate, Exos X18 data sheet Company says so
“Power-On Hours per Year (24×7) 8760”
Quote checked on the page, 8 Nov 2026 - Li, Yang, Islam, Ren (UC Riverside), Making AI Less Thirsty: water evaporated at the data centre per kWh Estimated
“data centers can evaporate approximately 1 – 9 liters per kWh of server energy”
Quote checked on the page, 8 Nov 2026 - Li, Yang, Islam, Ren (UC Riverside), Making AI Less Thirsty: water consumed at US power stations per kWh of electricity Estimated
“our value of 3.14 L/kWh for the U.S. average water consumption factor”
Quote checked on the page, 8 Nov 2026 - Andy Masley, independent blog (13 August 2025), his own sums from a drive data sheet and average water use Estimated
“To save as much water in data centers as fixing your toilet would save, you would need to delete 1.5 billion photos, or 200 billion emails.”
Quote checked on the page, 8 Nov 2026 - US EPA Estimated
“[28.446 Wh – (22 hours x 0.411 Watts)] x 1 kWh/1,000 Wh = 0.019 kWh/smartphone charged”
Quote checked on the page, 18 Oct 2026 - The Conversation (citing Lawrence Berkeley National Laboratory, 2024) Estimated
“U.S. data centers consumed 17 billion gallons”
Quote checked on the page, 18 Oct 2026
Hum’s sums
- One 18 TB data-centre drive idles at 5.3 W for 8,760 hours a year. Assume 1,000 photos of 5 MB each, kept as 3 copies: 15 GB. 5.3 × 8,760 ÷ 18 TB × 0.015 TB = about 39 Wh a year (the drive only).
- 0.019 kWh = 19 Wh
- 39 Wh ÷ 19 Wh per phone charge = about 2 phone charges a year
- 39 Wh × (1 litre per kWh at the data centre + 3.14 at the power station) = about 160 ml of water a year
- 39 Wh × (9 litres per kWh at the data centre + 3.14 at the power station) = about 470 ml of water a year
- A leaky loo’s 200 litres a day ÷ 470 ml = about 426 times as much water, every day
- 17 billion US gallons × 3.785 litres a gallon ≈ 64 billion litres
Cite this
UK Environment Agency and Defra, National Drought Group press release (August 2025), as quoted in Hum, “Will deleting old emails and photos really save water?”, https://humearth.org/q/delete-emails (quote checked 8 Nov 2026).
Cite the original source first; Hum is where you found it.
What do Wh, kWh and TWh mean?
Wh is a watt-hour: a 1-watt light left on for an hour. 1 kWh = 1,000 Wh, and 1 TWh = 1 billion kWh. Hum compares each number with something everyday so you don’t need the units.
Send this answer
Deleting old emails and photos won’t help in a drought. Keeping 1,000 photos for a year uses about 160 to 470 ml of water, by Hum’s sums. A leaky loo can waste 200 to 400 litres a day.